7.1 GENERAL
1. Maximum range: 16 Nautical Miles
2. Minimum range: Less than 25 m on the 0.125 NM range
3. Range scales: Range Number of Range ring
(NM) Rings Interval(NM)
0.125 2 0.0625
0.25 2 0.125
0.5 2 0.25
0.75 3 0.25
1.0 4 0.25
1.5 6 0.25
3.0 6 0.5
6.0 6 1.0
12.0 6 2.0
16.0 4 4.0
4. Range discriminations: Less than 25 m
5. Range ring accuracy: Better than ±0.9% of maximum range of
the scale in use, or 8 m, whichever is the
greater.
6. Bearing accuracy: ± 1 degree
7. Display device: LCD: 115 × 86.4 mm (320 × 240 dots)
8. Environmental conditions:
Scanner unit Temperature 15 to 55
Humidity Up to 95% at 35
Display unit Temperature
10℃ to + 50(Except LCD)
0 to 50 (LCD)
Humidity Up to 95% at 35
SPECIFICATIONS